About Polyurethane Feeding Tube
Gastrolene/Polyurethane feeding tube
- Tube is completely inert and non-reactive to gastric juices.
- Suitable for long term, extended usage of up to 4 weeks.
- Transparent tube for clear view to continuously monitor the contents.
- Soft rounded distal end with solid radio-opaque material sealed into the tube, to assist the passage of the tube during intubation and visualization of the tip on X-ray.
- Four lateral eyes for efficient enteral feeding and aspiration.
- Provided with full length yellow radio-opaque line for checking the tube placement and X-ray visualization.
- The tube is marked at 50, 60 and 70 cm from the tip for accurate placement.
- Proximal end provided with dual port mount connector for safe connection with catheter mount or luer mount syringe.
- Color coded for immediate size identification.
- Sterile, individually packed in a peelable pouch.
Universal Compatibility and Patient SafetyThe feeding tube offers a universal funnel connector that fits most hospital feeding systems. Its latex-free construction minimizes allergic risks, making it suitable for adult and pediatric patients. The kink-resistant tube and atraumatic rounded tip reduce the likelihood of tube obstruction and tissue injury during insertion and use.
Easy Placement and Reliable VisualizationWithdrawal markings at regular intervals allow clinicians to monitor insertion depth, enhancing placement accuracy. The radiopaque line embedded within the tube facilitates effortless visualization under X-ray, ensuring correct positioning for safe feeding or medication administration.
Sterility and Long Shelf LifeEach tube is individually packed in a peelable pouch and sterilized with ethylene oxide to maintain sterility until use. The feeding tube has a shelf life ranging from 2 to 5 years (depending on the manufacturer), provided it is stored in a cool, dry place away from direct sunlight.
FAQ's of Polyurethane Feeding Tube:
Q: How is the polyurethane feeding tube properly inserted and used?
A: The tube is manually inserted, with depth monitored using the withdrawal markings. Its atraumatic, rounded tip and soft material ensure minimal discomfort. Placement is confirmed by the radiopaque strip under X-ray, after which feeding or medication can be administered.
Q: What benefits does the radiopaque strip provide during the feeding process?
A: The radiopaque strip makes the tube visible under X-ray, allowing healthcare professionals to verify correct tube placement in the gastrointestinal tract and reduce complications related to misplacement.
Q: When should I use the polyurethane feeding tube, and for whom is it suitable?
A: This feeding tube is intended for adults and pediatric patients who cannot consume food or medication orally, such as those in hospitals with swallowing disorders, neurological issues, or requiring post-surgical nutrition support.
Q: Where can the feeding tube be used, and who typically utilizes it?
A: It is primarily used in hospital settings by trained medical professionals including doctors and nurses, for both short-term and long-term enteral feeding.
Q: What are the safety features of this feeding tube?
A: Safety features include a latex-free and biocompatible material, a kink-resistant design for uninterrupted flow, an atraumatic tip to minimize tissue injury, sterile EO processing, and clear withdrawal markings for accurate placement.
Q: How should the feeding tube be stored to maintain its sterility and shelf life?
A: Store the individually packaged tube in a cool, dry place away from sunlight, ensuring the packaging remains intact to maintain sterility and maximize its 2-5 year shelf life.
Q: What is the process for disposing of the tube after use?
A: Following single use, the tube should be disposed of in accordance with hospital protocols for medical waste, as it is designed for one-time use only to prevent infection and cross-contamination.